Stochastic Model Based Optimisation Path Study of Off-grid Optical Storage Microgrid Configuration and Economy
, , , , und
17. März 2025
Über diesen Artikel
Online veröffentlicht: 17. März 2025
Eingereicht: 13. Okt. 2024
Akzeptiert: 26. Jan. 2025
DOI: https://doi.org/10.2478/amns-2025-0184
Schlüsselwörter
© 2025 Kan Feng et al., published by Sciendo
This work is licensed under the Creative Commons Attribution 4.0 International License.
Figure 1.

Figure 2.

Wind speed, light intensity, temperature and latency load in a region
Time | Wind speed (m/s) | Illumination intensity (°/ |
Ambient temperature (°C) | Latency load (kW) |
January | 3.23 | 2.4 | -7.5 | 51.7 |
February | 4.38 | 2.85 | -4.6 | 45.5 |
March | 3.6 | 3.15 | 2.5 | 48.7 |
April | 2.94 | 4.02 | 9.4 | 50.7 |
May | 2.88 | 4.17 | 13.6 | 45.8 |
June | 2.72 | 6.91 | 22.7 | 49.8 |
July | 2.84 | 6.16 | 25.9 | 48.2 |
August | 4.1 | 6.01 | 22.8 | 51.6 |
September | 3.81 | 5.32 | 19.2 | 48 |
October | 4.02 | 4.87 | 8.9 | 48.5 |
November | 4.28 | 4.73 | -0.4 | 45.8 |
December | 4.21 | 4.51 | -5.8 | 50.9 |
Cost parameters of the net type optical storage micronet equipment
Device name (yuan/kW) | Installation cost | Replacement cost | Operating maintenance cost | Service life (Year) | Fuel cost |
Wind generator (WT) | 15000 | —— | 0.09% | 25 | —— |
Photovoltaic cell (PV) | 14500 | —— | 0.05% | 25 | —— |
Photovoltaic MPPT | 700 | —— | 0.06% | 25 | —— |
Diesel generator (Gen) | 850 | 590 | 0.74 yuan/h | 17500h | 5.08 yuan/L |
Fuel cell (FC) | 16800 | 14200 | 0.19 yuan/h | 55000h | —— |
Electrolytic cell (ELE) | 7840 | —— | 0.03% | 25 | —— |
Hydrotank (HT) | 2600 | —— | 0.78% | 25 | —— |
Flow converter | 4800 | —— | 0.98% | 25 | —— |
Accumulator | 1500 | 950 | 1.15% | 3 | —— |
Gas boiler | 600 | —— | 1.5% | 25 | 3.52 yuan/ |
Microgrid controller | 18000 | —— | 0.95% | 25 | —— |
Optimize the configuration results of the energy storage system
Scheme type | WT | PV (kW) | MPPT (kW) | Gen (kW) | Battery | Converter (kW) | FC (kW) | ELE (kW) | HT (kg) |
A1 | 55 | —— | —— | —— | 2500 | 356.1 | —— | —— | —— |
B1 | 55 | —— | —— | —— | 2900 | 334.8 | —— | —— | —— |
A2 | —— | 450 | 450 | —— | 2900 | 85.9 | —— | —— | —— |
B2 | —— | 450 | 450 | —— | 3200 | 83.1 | —— | —— | —— |
A3 | 18 | 320 | 320 | —— | 2400 | 95.4 | —— | —— | —— |
B3 | 18 | 320 | 320 | —— | 2500 | 91.8 | —— | —— | —— |
A4 | 15 | 290 | 290 | 40 | 600 | 102.3 | —— | —— | —— |
B4 | 15 | 290 | 290 | 40 | 1200 | 98.7 | —— | —— | —— |
A5 | 15 | 290 | 290 | —— | 650 | 36.5 | 45 | 18 | 18 |
B5 | 15 | 290 | 290 | —— | 1200 | 58.4 | 45 | 18 | 18 |
Optimize economic indicators
Scheme type | NPC (yuan) | LCOE (yuan) | REU (%) | LLR (%) |
A1 | 24655595.11 | 2.83 | 94.78 | 10.23 |
B1 | 26666925.18 | 2.86 | 94.78 | 10.23 |
A2 | 24184924.71 | 2.44 | 94.78 | 9.26 |
B2 | 24652862.85 | 2.71 | 94.78 | 9.16 |
A3 | 23957793.8 | 2.23 | 94.82 | 6.81 |
B3 | 24080801.53 | 2.3 | 94.82 | 6.34 |
A4 | 17754849.7 | 1.71 | 80.87 | 6.08 |
B4 | 19972982.57 | 1.73 | 81.35 | 5.92 |
A5 | 12169284.2 | 1.51 | 99.86 | 5.49 |
B5 | 13053573.8 | 1.68 | 98.64 | 4.89 |
Comparison of cost changes under different scenarios
Project | Original scene | New scene |
Photovoltaic installation (yuan) | 25481635.52 | 22635487.92 |
Replacement cost (yuan) | 42563.25 | 39425.62 |
Operating maintenance cost (yuan) | 11524.63 | 10524.63 |
Photovoltaic subsidy cost (yuan) | 27846.24 | 25146.62 |
Net loss cost (yuan) | 1852.64 | 1524.28 |
Light storage rate | 13.24% | 16.47% |
Voltage deviation indicator | 0.8215 | 0.7942 |
Net loss index | 0.3265 | 0.3148 |
Wind speed and solar radiation statistics
Season | Wind velocity distribution parameter | Wind velocity wibull distribution parameters | ||
Spring | 2.65 | 5.94 | 2.16 | 0.45 |
Summer | 1.74 | 6.34 | 2.99 | 0.72 |
Autumn | 2.59 | 6.85 | 2.34 | 0.59 |
Winter | 2.74 | 6.92 | 2.07 | 0.45 |
Average annual | 2.43 | 6.51 | 2.39 | 0.55 |