Intelligent Algorithm-Based Modeling of Lighting and Thermal Environment Balance in Green Buildings
21 mar 2025
INFORMAZIONI SU QUESTO ARTICOLO
Pubblicato online: 21 mar 2025
Ricevuto: 07 nov 2024
Accettato: 19 feb 2025
DOI: https://doi.org/10.2478/amns-2025-0581
Parole chiave
© 2025 Hui Xiong, published by Sciendo
This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
Figure 1.

Figure 2.

Figure 3.

Figure 4.

Figure 5.

Figure 6.

Figure 7.

Figure 8.

Figure 9.

Figure 10.

Figure 11.

Figure 12.

Figure 13.

Eastbound Pareto solution set
ID | Width | Angle | Altitude | Energy-saving effect/% | UDI variation/% |
---|---|---|---|---|---|
1 | 2.2 | 32 | 1.1 | 51.26 | -6.24 |
2 | 2.2 | 38 | 1.2 | 51.29 | -4.73 |
3 | 2.2 | 33 | 1.3 | 50.04 | -1.21 |
4 | 2.2 | 35 | 1.4 | 49.92 | -1.15 |
5 | 2.2 | 38 | 1.5 | 49.28 | 0.04 |
6 | 2.2 | 32 | 1.8 | 48.97 | 0.25 |
7 | 2.2 | 23 | 1.7 | 47.65 | 1.41 |
8 | 2.2 | 23 | 1.5 | 47.54 | 1.62 |
9 | 2.2 | 18 | 1.8 | 46.32 | 1.76 |
10 | 2.2 | 14 | 1.8 | 45.91 | 1.91 |
Lighting standard values on the reference plane of each lighting level
Lighting level | Side lighting | Overhead lighting | ||
---|---|---|---|---|
Standard value of lighting coefficient/% | Standard value of indoor natural illumination/lux | Standard value of lighting coefficient/% | Standard value of indoor natural illumination/lux | |
I | 5 | 750 | 5 | 750 |
II | 4 | 600 | 3 | 450 |
III | 3 | 450 | 2 | 300 |
IV | 2 | 300 | 1 | 150 |
V | 1 | 150 | 0.5 | 75 |
Southbound Pareto solution set
ID | Width | Angle | Altitude | Energy-saving effect/% | UDI variation/% |
---|---|---|---|---|---|
1 | 2.2 | 38 | 1.7 | 76.24 | -0.27 |
2 | 2.2 | 41 | 1.7 | 76.42 | -0.23 |
3 | 2.2 | 42 | 1.8 | 76.25 | 1.05 |
4 | 2.2 | 35 | 1.8 | 76.24 | 1.14 |
5 | 2.2 | 38 | 1.8 | 76.23 | 0.26 |
6 | 2.2 | 32 | 1.8 | 76.04 | 3.47 |
7 | 2.2 | 28 | 1.8 | 75.38 | 2.69 |
8 | 2.2 | 29 | 1.7 | 75.24 | 2.21 |
9 | 2.2 | 26 | 1.8 | 75.22 | 3.42 |
10 | 2.2 | 23 | 1.8 | 74.36 | 3.48 |