Research on Reinforcement Learning Based Regulation Scheme for Renewable Energy System in Green Buildings
et
21 mars 2025
À propos de cet article
Publié en ligne: 21 mars 2025
Reçu: 22 oct. 2024
Accepté: 02 févr. 2025
DOI: https://doi.org/10.2478/amns-2025-0607
Mots clés
© 2025 Yin Li et al., published by Sciendo
This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
Figure 1.

Figure 2.

Figure 3.

Figure 4.

Figure 5.

Related parameters
Window size/m2 | Building heat capacity/(J·K-1) | Thermal resistance between indoor and environment/(K·W–1) | Ashp heating power/kW |
---|---|---|---|
10 | 7453000 | 5.28×10–3 | 2 |
Operation strategy of heat pump and energy storage
Operation strategy of heat pump | |||
---|---|---|---|
Room temperature |
Electrovalence |
||
0.35< |
|||
Low | 1 | 1 | 0.75 |
Medium | 0.75 | 0.75 | 0.5 |
High | 0.25 | 0 | 0 |
Operation strategy of energy storage | |||
Photovoltaic power generation |
Electrovalence |
||
0.35< |
|||
Low | -1 | -1 | -1 |
Medium | 1 | 0 | 1 |
High | 1 | 0 | 1 |
Robustness of DDPG
Scheme | Operating cost(RMB) | ATV(°C) | ||||
---|---|---|---|---|---|---|
0.9°F | 1.8°F | 2.4°F | 0.9°F | 1.8°F | 2.4°F | |
Scheme 1 | 3023 | 3034 | 3029 | 0.182 | 0.186 | 0.235 |
Scheme 2 | 2392 | 2406 | 2407 | 0.182 | 0.186 | 0.235 |
Scheme 3 | 2204.34 | 2263.91 | - | 0 | 0 | - |
DDPG | 2181.3 | 2284.4 | 2284 | 0.003 | 0.005 | 0.075 |