Research on the effects of ferric salt added into aeration tank for phosphorus removal on biochemical system
, , , y
10 nov 2021
Acerca de este artículo
Publicado en línea: 10 nov 2021
Páginas: 281 - 290
Recibido: 25 may 2021
Aceptado: 23 jul 2021
DOI: https://doi.org/10.2478/amns.2021.2.00041
Palabras clave
© 2021 Xie Jingliang et al., published by Sciendo
This work is licensed under the Creative Commons Attribution 4.0 International License.
Fig. 1

Fig. 2

Fig. 3

Fig. 4

Main instrument table for testing_
Experimental device | Type |
---|---|
Digital electronic analytical balance | AUY220 |
Precise PH meter | PHS-3C |
Vacuum extractor | MC-600D |
Stirrer used in coagulation test | ZR4-6 |
Magnetic stirrer | MS7-H550-Pro |
Silent air pump | AP9903A |
UV spectrophotometer | UVmini-1240 |
Pure water test_
Test I | Initial pH | The pH after aeration | ||
Pure water | 6.4 | 6.3 | ||
Tap water | 7.7 | 8.3 | ||
Test II | Initial pH | The pH after filling in CO2 | The pH after aeration | |
Pure water | 6.2 | 5.3 | 6.4 |