A Comparison between Integer and Fractional Order PDμ Controllers for Vibration Suppression
, , and
May 23, 2016
About this article
Published Online: May 23, 2016
Page range: 273 - 282
Received: Mar 29, 2016
Accepted: May 17, 2016
DOI: https://doi.org/10.21042/AMNS.2016.1.00022
Keywords
© 2016 Isabela R. Birs, Cristina I. Muresan, Silviu Folea, and Ovidiu Prodan, published by Sciendo
This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 3.0 License.
Along the years, unwanted vibrations in airplane wings have led to passenger discomfort. In this study, the airplane wing is modeled as a cantilever beam on which active vibration suppression is tested. The paper details the tuning of both integer and fractional order Proportional Derivative type controllers based on constraints imposed in the frequency domain. The controllers are experimentally validated and the results prove once more the superiority of the fractional order control approach.